MRL Cooling Tower Software
MRL software was developed for cooling towers by industry expert, Marcel Lefevre. Marcel Lefevre's cooling tower career spanned over 50 years and his software has been in use by leading cooling tower manufacturers and rebuild specialists around the world since 1988.
MRL software now runs on any computer with MS Windows operating system 7, 8,10 & 11 with either 32 or 64-bit microprocessors. The software is provided on a 8 GB, copy-protected USB flash drive and is completely portable, which means no installation is required. It runs in a self-contained, emulated DOS window.
​
JS Resources, Inc. is an exclusive distributor of MRL software for the Korean market since 1995.
IDCF - Rating/sizing of evaporative, induced-draft, counter flow cooling towers
-
Design a new induced draft cooling tower based on design conditions or predict performance of an existing cooling tower
-
Includes the latest fill data from leading suppliers
IDXF - Rating/sizing of evaporative, induced-draft, cross flow cooling towers
-
Design a new induced-draft cross flow cooling tower based on design conditions or predict performance of an existing cooling tower
-
Includes the latest fill data from leading suppliers
FDCF - Rating/sizing of evaporative, forced-draft, counter flow cooling towers
-
Design a new forced-draft counter flow cooling tower based on design conditions or predict performance of an existing cooling tower
-
Includes the latest fill data from leading suppliers
NDCF - Rating/sizing of evaporative, natural-draft, counter flow cooling towers
-
Design a new natural draft cooling tower based on design conditions or predict performance of an existing cooling tower
-
Fill sections can be comprised of up to three different fills
-
The fill plan area can be segmented into 16 concentric rings for exacting fill placement
NDXF - Rating/sizing of evaporative, natural-draft, cross flow cooling towers
-
Design a new natural-draft cross flow cooling tower based on design conditions or predict performance of an existing cooling tower
-
Includes the latest fill data from leading suppliers
CFPC - Performance curve plotting for induced-draft cooling towers
-
For both induced-draft counter flow and cross flow towers (not applicable for natural draft)
-
Produces performance curves that meet CTI ATC-105 criteria (WBT vs CWT, with range as the parameter for each water flow)
-
Graphs can be printed to a PDF printer or directly to a hard copy printer
Software notes:
-
All software utilizes dual units (US customary and SI) except where noted
-
IDCF, IDXF, FDCF and NDCF can model cooling tower performance with both fresh and seawater
-
All software is copy protected. Source code is not provided
-
The look and feel of the software is exactly like the version provided by MRL on 3.5 in. floppy disks. It is pure DOS and as such, not mouse active
-
A completely revised PowerPoint user manual in PDF format is included on the USB flash drive for all programs purchased